Related Links
Product Overview
A-Z Alphabetically
Literature
Request Demo CD
Request Proposal
 
 
Quality Assurance

ISO 9001:2000 Standard
United States Code of
Federal Regulations
10 CFR 50
10 CFR 21
ANSI/ASME N45.2
ASME NQA-1
ANSI/IEEE Std 730.1
CAN/CSA-Q396.1.2
Ground Grid Systems

The next generation Ground Grid Systems module enables engineers to quickly and accurately design and analyze ground protection.

Advanced 3-D technology integrates with one-line diagrams, enabling engineers to visualize their ground systems and seamlessly utilize short circuit results.

Flexible design methodologies allow for quick auto-designed layouts or very detailed schemes. Color-coded graphical plots provide impressive results.

Finite Element Method
  • 3-D plots for step, touch, & absolute potentials
  • 3-D irregular configurations
  • 3-D graphical interface views
  • Rods & conductors in any direction
  • Graphical display of over limits
    (see DataX - CAD Interface)
IEEE 80 & 665 Methods
  • Conductor & rod optimization
  • 3-D graphical interface views
Capabilities
  • Handle irregular configurations of any shape
  • Optimize number of conductors with fixed rods
  • Optimize number of conductors & rods based on cost
  • Check the allowable current for grid conductors
  • Compare allowable currents against fault currents
  • Compare potentials to tolerable limits
  • Automatically use short circuit results
  • Two-layer soil configuration plus surface material
  • Table of potentials at the earth surface
  • External boundary extensions
  • Variable weight & temperature options
  • User-expandable conductor library
  • Ground grid configurations showing conductor & rod plots
  • Reflection factor (K)
  • Decrement factor (Df)
  • Ground potential rise (GPR)
  • Ground system resistance (Rg)
  • Surface layer derating factor (Cs)
  • Step, touch, & absolute potentials inside & outside grid
Plot Options
  • Rotation animation
  • Rotation increment (-15 to 15 degrees)
  • Rotation detail – wire frame/plotting style/full detail
  • Viewing style – color/monochrome
  • Shading style – white/color
  • Font size – small/medium/large
  • Numeric precision – 0, 1, 2, 3 decimals
  • Grid lines – no grid, X and/or Y axes
  • Plotting method – wire frame/surface/surface with
    frame/surface with contouring/pixels
  • Show bounding box while rotating always/never
  • 2-D contour
  • Off
  • Lines on top/bottom
  • Color on top/bottom
Reporting
  • 3-D touch potential plots
  • 3-D step potential plots
  • 3-D absolute voltage plots
  • Color coded contour plots
  • Graphical display of over limit voltages
  • Conductor segments oriented in any 3-D direction
  • Output results in Microsoft Access databases & Crystal Reports