ETAP's Harmonic Analysis module, you can identify harmonic problems, reduce nuisance trips, design and test filters, and report distortion limit violations. Comprehensive load flow and frequency scan calculations are performed using detailed harmonic models and non-integer harmonic filters. Results are shown graphically, including harmonic order, harmonic spectrum plots, and harmonic waveform plots, as well as Crystal Reports. |
|
- IEEE 519 Standard
- Automatic distortion evaluation (THD & IHD)
- Telephone influence factors (TIF & I*T)
- Automatic alerts of violations
- Harmonic sources library
|
|
- User-definable frequency range
- Identify resonance conditions
- User-customizable plots
|
| |
- Filter design & sizing
- Single-tuned, high-pass, & band-pass filters
- Automatic filter overloading alert
- Inter-harmonic filter modeling
|
|
- User-expandable harmonic source library
- Voltage & current harmonic sources
- Consider both harmonic source magnitudes & phase angles
- Harmonic source based spectrum or device parameters
- Model up to the seventy-third (73rd) harmonic
- Temperature-dependent line & cable resistances
- Automatic adjustment of equipment impedance to harmonic frequency
- Includes phase shifting transformers
- Build-in single-tuned, high-pass, & band-pass filter models
- Create filters to shift resonance points to less harmful frequencies
- Identify harmonic distortion problems
- Identify & analyze telephone interference problems
- Identify parallel resonance conditions
- Fundamental load flow results
- Bus impedance magnitude & angle as functions of frequency
- IEEE 519 defined harmonic indices
- Total & individual voltage & current
- Harmonic Distortions (THD & IHD)
- Root Mean Square Values (RMS)
- Voltage Arithmetic Summation (ASUM)
- Telephone Interference Factor (TIF)
- I*T product
- Time-domain waveform plots
- Frequency-domain spectrum plots
- Harmonic filter performance evaluation
- Magnitude & angle of the system impedance at selected buses
|
|
|
|
|
- Report voltage & current harmonic distortions
- Report RMS, ASUM, TIF, & I*T values
- Bus impedances (magnitude & angle) tabulation
- Text output reports including violation flags
- Graphical one-line display of harmonic results
- Voltage & current harmonic spectrum plots
- Bus driving point impedance scan curves
- Export one-line diagrams to third party CAD systems
- Fundamental load flow results
- Use Crystal Reports® for full color, customizable reports
- Export output reports to your favorite word processor
|
|
|
|
|
|
|
|
|